Description
– Input Signal (INPUT): 0 to 20 mA; 4 to 20 mA (check minimum current for proper operation)
– Maximum Input voltage (Vin max.): 32 Vdc
– Voltage Drop (Vdrop): < 3 Vdc
– Output Signal (OUTPUT): 0(4) to 20 mA
– Max. Load (RL): 1450 R
– Accuracy: 0.2 % FS @ 0 a 60 °C / RL= 250 R; 0.3 % FS @ -20 a 75 °C / RL= 250
– Operating current: > 0.1 mA
– Overload: < 40 mA; < 32 Vdc
– Response time: 2 ms @ RL= 250 R
– Isolation: 3000 Vac / 10 s; 240 Vac continuous
– EMC: EN 61326-1
– Ambient temperature range: -20 to + 75 °C
– Humidity: 20 to 90 % RH
– Protection: IP40
– Wire gauge for connections: 0.14 to 1.5 mm²
– Recommended torque: 0.8 Nm
– Terminal blocks injected in Polyamide