Description
C62 Panel Mount 1/16 DIN
FDC Multi-Color LCD display C-Series set a standard for DIN temperature controllers packed with performance to meet low-cost OEM needs while providing reliable High-Performance temperature and process control.
Options:
- Power Input:
- 90-264VAC
- Output 1:
- Form A Relay
- Type:
- 1/16 DIN
FDC-C62-4-1-0-0-0-0-0-0-00, Temperature 1/16 DIN Controller, 90-264VAC, Form A Relay
Applications:
|
Features:
|
|||||
|
|
|
The New C-Series High-Performance PID Process Control
The Multi-Color LCD display C-Series set a new standard for DIN temperature controllers packed with performance to meet low-cost OEM needs while providing reliable High-Performance temperature and process control with a 3-Year Warranty.
C-Series Panel Mount Sizes
The C-Series is available in 1/32 DIN C22, 1/16 DIN C62, 1/8 DIN C82/83, 1/4 DIN C42, and R22 DIN Rail Mount. The 1/8 DIN is available as vertical and horizontal while the R22 is a DIN rail mount control perfect for high-density single-loop control requirements.
Ease of Use:
The multi-color LCD display, configurable space for output annunciation, PID % output, count-down timer or Profile information provide operators with an ease of use not found in this class of instruments. In addition, the SEL function provides additional flexibility & operator ease of use by allowing configuring those parameters significant to the operator [up to 8] to display in sequence when the scroll key is depressed. [P, I, D, Shift, Cycle 1, deadband, etc., or nothing displayed].
Input Resolution and Auto-Tune:
With the highest input resolution for like products, fast scan rate, and proprietary Fuzzy Logic Auto-Tune the C-Series provides world-class control performance.
Control Outputs:
Dependent upon the model the C-Series is available with up 4 control outputs which can be configured up to 2 PID or 1 PID with 3 alarm or event combinations, In addition, optional Serial Modbus, Retransmission, Remote Setpoint, configurable Event inputs, CT inputs and more.
Alarm Configuration:
There are 11 different alarm types including Process, Deviation, Deviation Band, CT Heater Break/Short, and Event input (mapped to relay output) all with Latching, non-Latching, Alarm Hold, and individually configurable time delay to minimize nuisance alarms. Profile end, Profile in Holdback, Range High / Low and Dwell time alarm providing a count-down timer starting when the alarm is activated; the dwell time remaking may be displayed on the1 /8 & 1/4 DIN models…
Ramp to Setpoint:
All models include a configurable Ramp Rate to setpoint in degrees per minute or hour with a Soak Alarm available for all models..
Profile (Ramp Soak):
The 1/8 and 1/4 DIN C82/83 and C42 offer Profile ramp/soak function supporting up to 16 steps. Configurable as 1 profile with 16-steps, 2 profiles with 8 steps each, or 4 profiles with 4 steps each. Outputs other than output #1 may be configured as event outputs. The profile status may be displayed; refer to the user manual for additional details.
Remote Setpoint (analog input):
Available in the 1/8 DIN C82/83 and 1/4 DIN C42.
Soft Start::
– Steady-state, non-profile control, or if Profile capable, not running a profile:
-
- On power, up a configured percentage of the proportional output for outputs 1 and 2 if 2 is PID cool.
- Configurable to terminate on time or the PV crossing a configured threshold…
– Profile Capable and running a Profile:
– Power Cycle, will operate as described above (steady state) if Profile Recovery (PFR) is set to SPI. If set to another PFR value the Soft Start logic will not be active.
– If Soft Start-end is configured as passing a PV threshold the time of power-up is not relevant when PFR = SP1 as long as the PV is below the threshold value.
refer to the user manual for additional information.
Event Input:
Multiple mutually exclusive configurable functions are available for profile control, reset latching alarms, defeat outputs, start AutoTune, Output Failure Transfer, alarm input mapped to a relay output, and more…
– 1 Event Input offered on the 1/32 DIN and DIN Rail mount models C22/R22.
– 2 Event Inputs offered on the 1/16 DIN C62
– 6 Event Inputs offered on the 1/8 DIN C82/83 and 1/4 DIN C42
Communication:
All models support
– Serial Modbus RS485
– Retransmission of SP or PV, mA or VDC
Load User (Custom) Default Configuration:
The device configuration as commissioned by the OEM or end user may be set as the device’s default configuration. Navigating to the “load default configuration” prompt the operator may easily return the device to a known configuration.
Manual Loading Station: Instead of being used as a PID control the 100 & C Series may be configured as a Manual Loading Station to provide an easy method to manually control a linear output. The single-display C Series is the most popular model for Manual Stations. Additional information can be found at Loop Controls Manual Loading Station.pdf
OEM or Distributor Private Branding is available.
______________________________________________
Specification Review
- Power Input:
- 90-250VAC 47-63Hz
- 11-40VDC / 20-28VAC 47-63Hz optional
- Input sample rate – 5 scans/second
- Input Resolution – 18 Bit [262,144]
- Inputs – Universal Thermocouple & RTD, Linear mA/VDC (standard)
- Control Outputs: Up to 2 isolated PID control outputs; to have two PID outputs #1 must be PID & output #2 is default PID Cool .
- Available outputs are:
-
- relay 2A/240 VAC resistive [form A (spst)]
- SSRD 5VDC/30mA
- SSRD 14VDC/40mA
- 4-20/0-20mA
- 0-10VDC
-
- Alarm Outputs:
- depending upon model and configuration up to 3 outputs. Output #2/Alarm #2 may be specified as any control output shown above while the remaining alarm outputs are relay (Form A (spst)).
- Communications: Modbus RS232, RS485, VDC and mA retransmission.
- Transmitter Power Supply [isolated] is available.
- Security: Software configurable – allows
- None: All parameters are unlocked
- Set: Setup Configuration Data is locked
- User: All data locked except SP#1
- All: All data locked